Siemens SIMADYN D Manual page 198

System- and communication configuring
Hide thumbs Also See for SIMADYN D:
Table of Contents

Advertisement

Communications reference
Association type
Remote address
Max. PDU length
Password
Profile
Supported utility
Read
Get OV (detailed version)
Max. No. of parallel tasks:
Transmitting
Table 3-48
Mask, "Non-cyclic client"
System- and communication configuring D7-SYS - SIMADYN D
Edition 12.2003
:
:
:
:
241
:
0
:
0
0
:
:
no
:
no
:
1
Rules:
• The communications reference must correspond with the CFC
configuring (address stage 1 at address I/O).
• "MMAZ" is the association type when establishing a connection to a
master (e. g. SIMADYN D or SIMATIC) or "MSZY" when establishing
a connection to a slave.
• Local LSAP is uncritical, if the server association is "open" otherwise it
must correspond with "Remote LSAP" for the server.
• Remote address and remote LSAP uniquely address the server.
• Max. PDU length should only be changed if the server cannot handle
the specified length.
• The monitoring interval must correspond with that of the server.
Communications configuring
Type
Non-cyclic client
:
Local LSAP
Remote LSAP
Monitoring interval
Group
Write
Symbolic addressing
Receiving
Name :
:
:
:
0 s
:
0
:
no
:
no
:
0