■ PANEL DUCT ASSY - 5
Wiring of PANEL DUCT assy (internal/external air sensor and PANEL FAN) 2
(1) Wiring of CNFL1 and CNFL2
Take out CNFL1/CNFL2 connected to internal air sensor PCB/external air sensor PCB through the side opening of PANEL DUCT,
then pass them through the clamp to wire in the direction of PANEL FAN cables.
PANEL FAN leads
Pass CNFL1 and CNFL2 through this clamp.
(2) Wiring of R PANEL FAN, G PANEL FAN, and B PANEL FAN
Take out the leads of PANEL FANs (R FAN, G FAN, and B FAN) attached inside
the PANEL DUCT through the slits in dotted red circles as shown below.
View of inside of the PANEL DUCT from below
R PANEL FAN
Magnified
picture
Take out the leads of PANEL FANs through these slits.
Make sure that the leads are not coming off from the slit hooks.
(Magnified picture)
View of the slits of the PANEL DUCT from above
The leads of PANEL FANs viewed from the slits of
PANEL DUCT UPPER.
Connect them to the connectors of the MAIN PCB with this state.
LWU650-APS/LWU530-APS
Service Manual
LWU650-APS / LWU530-APS
Overall view of the PANEL DUCT
Take CNFL1 and CNFL2 out of the duct
through this opening.
Magnified
picture
G PANEL FAN
B PANEL FAN
Magnified
picture
Magnified
picture
Magnified
picture
69
020-001522-01 Rev. 1 (11-2018)