The projector does not start up /
the light source does not light.
Not lighting
What is the status of
indicators?
Others
Check a pattern of LED indicator.
Legend: [POWER/STATUS : STATUS DETAIL ]
YES
Is it COVER ERROR?
[4:0]
NO
YES
Is it FAN ERROR?
[7:X]
NO
YES
Is it
LIGHT SOURCE ERROR?
[3:0]
NO
Is it
YES
PHOSPHOR WHEEL
ERROR?
[8:1]
NO
Is the pattern of LED indicator any of the
following?
[2:1]: Internal temperature error
[2:2]: External temperature error
[2:3]: LD temperature error
[2:4]: Phosphor wheel temperature error
YES
A
LWU650-APS/LWU530-APS
Service Manual
LWU650-APS / LWU530-APS
YES
Is the problem
solved after re-attaching
UPPER CASE?
NO
Replace MAIN PCB.
Replace a faulty FAN or MAIN PCB.
The number of X is:
1: [E807]: PANEL DUCT FAN R
2: [E802]: PANEL DUCT FAN G
3: [E803]: HEAT SINK FAN 1
4: [E804]: HEAT SINK FAN 2
5: [E805]: POWER PCB FAN
6: [E806]: PHOSPHOR WHEEL FAN
7: [E801]: PANEL DUCT FAN B
Is the problem
YES
solved after re-inserting
cable (CNLPW)?
NO
Replace any of the following:
Light source unit (LD failure)
POWER UNIT CIRCUIT
MAIN PCB
Is the problem
YES
solved after re-inserting
FFC cable of PHOSPHOR
WHEEL (EW71)?
NO
Replace either of the following:
Light source unit (PW failure)
MAIN PCB
Power on after opening
UPPER CASE.
Measure voltage of E800.
1pin (approx. 17V)
5pin (approx. 5V),
9pin (approx. 17V)
NG
Power off, and measure
resistance after removing E800.
Between 1pin and 2pin,
5pin and 6pin, 11pin and 13pin
OPEN
Replace
POWER UNIT CIRCUIT.
Execute the following procedure step by step:
1. Check external air temperature and altitude
2. Check that intake vent/exhaust vent are 50cm or more away from surrounding wall.
3. Check if intake vent is clogged.
→If it is dirty, clean it by using a vacuum cleaner.
4. Replace a faulty part
[2:1]: Internal temperature error
Replace internal air temperature sensor.
[2:2]: External temperature error
Replace external air temperature sensor.
[2:3]: LD temperature error
Are there any damages on heat pipes?
Is light source in failure?
Are there any problems with wiring of LD temperature sensor and MAIN PCB?
→If not, replace LD temperature sensor.
[2:4]: Phosphor wheel temperature error
Is light source in failure?
Are there any problems with wiring of phosphor wheel temperature
sensor and MAIN PCB?
→If not, replace phosphor wheel temperature sensor.
Completed
21
OK
0
Replace MAIN PCB.
A
020-001522-01 Rev. 1 (11-2018)
LIT MAN SERV APS Series