Christie APS Series Service Manual page 12

Hide thumbs Also See for APS Series:
Table of Contents

Advertisement

5-2 Regarding the indicator
When operation of the POWER/STATUS and STATUS DETAIL indicators differs from usual, check
and cope with it according to the following table.
See also diagnosis flowchart in chapter 6 when some error happens.
POWER/STATUS
indicator
Lighting
Orange
In
Blinking
Green
In
Lighting
In
Green
Blinking
Orange
In
Blinking
Red
In
3 times
Blinking
Red
In
7 times
Blinking
Red
In
2 times
Blinking
Red
In
1 time
LWU650-APS/LWU530-APS
Service Manual
LWU650-APS / LWU530-APS
STATUS
DETAIL
indicator
Turned
The projector is in a standby state.
off
Please refer to the section "Power on/off".
Turned
The projector is warming up.
off
Please wait.
Turned
The projector is in an on state.
off
Ordinary operations may be performed.
The projector is cooling down.
Turned
off
Please wait.
The light source does not light. There is a
possibility that interior portion has become
heated, or that the power supply is unstable.
Please turn the power off, and allow the projector to
Blinking
cool down at least 20 minutes. After the projector has
Red
In
sufficiently cooled down, please make confirmation of
0 ~ 5 times
the following items, and then turn the power on again.
• Is there blockage of the air passage aperture?
• Is the air filter dirty?
• Does the peripheral temperature exceed 40°C?
The cooling fan is not operating.
Please turn the power off, and allow the projector to
cool down at least 20 minutes. After the projector has
Blinking
sufficiently cooled down, please make confirmation
Red
In
that no foreign matter has become caught in the fan,
1 ~ 7 times
etc., and then turn the power on again.
If the same indication is displayed after the remedy,
please contact your dealer or service company.
The internal temperature is rising.
Please turn the power off, and allow the projector to
cool down at least 20 minutes. After having confirmed
Turned
the following items, please turn the power on again.
off
• Is there blockage of the air passage aperture?
• Is the air filter dirty?
• Does the peripheral temperature exceed 40°C?
It is time to clean the air filter.
Please immediately turn the power off, and clean or
Turned
change the air filter referring to the section "Cleaning
off
and replacing the air filter". After cleaning or changing
the air filter, please be sure to reset the filter hours.
After the remedy, turn the power on.
Description
11
020-001522-01 Rev. 1 (11-2018)
LIT MAN SERV APS Series

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lwu650-apsLwu530-aps

Table of Contents