Wiring of MAIN PCB -2
Connection of R/G/B panel flexible cable
Before panel flexible cable connected
After panel flexible cable connected
Leave panel flexible cables
with excessive length on PCB
after inserting them.
Procedure for removing panel flexible cables
1
2
3
LWU650-APS/LWU530-APS
Service Manual
LWU650-APS / LWU530-APS
Open the stopper (marked with a dotted line)
upwards before inserting panel flexible cable.
[NOTE]
Handle panel flexible cable with care
because it is fragile.
Do not bend it in order not to disconnect.
Tilt the stopper (marked with
a dotted line) to fix after
inserting panel flexible cable.
Open the stopper (marked with a dotted line)
upwards to remove a panel flexible cable.
Hold both edges of the panel flexible cable
(marked with a dotted line) with fingers of
both hands.
Make sure not to damage the cable.
Do not bend it by applying too much force.
Holding the panel flexible cable, pull it out from
the connector slowly to the direction indicated
by a yellow arrow.
Do the same for other 2 cables.