Christie APS Series Service Manual page 90

Hide thumbs Also See for APS Series:
Table of Contents

Advertisement

10-9 LD MENU
This indicates lighting time of light source. If a light source has been replaced, initialize lighting time by
moving a cursor to lighting time.
Remote control: Hold down the RESET button.
Keypad: Hold down the ↓ and INPUT button at the same time.
This menu indicates brightness of light source which is measured by light sensor. It is recommended to
replace the light source unit if this value is less than 350.
This indicates max value of light source output power. If a light source has been replaced, initialize max
value of light source output power. Select MaxCur and perform the following operation.
Remote control : Hold down the RESET button.
Keypad : Hold down the INPUT button.
This indicates the calibration result of duration which a sensor measures the electric charge. If a light
source has been replaced, execute calibration of duration.
When you select Calib and press the → button, another window is displayed as shown above. When you
press the → button again and select OK, calibration starts. Calibration finishes in about 30 seconds after it
started, and a cursor moves to END.
LWU650-APS/LWU530-APS
Service Manual
LWU650-APS / LWU530-APS
89
020-001522-01 Rev. 1 (11-2018)
LIT MAN SERV APS Series