■ PANEL DUCT ASSY - 3
Attachment of sensor PCB
WORK CAUTION
Make sure that the sensor PCB is attached in the lower position
than the top end of rib of the PANEL DUCT BTM B AS by 1.2mm or more.
OK
PNL DUCT BTM B AS
Bad
Bad
LWU650-APS/LWU530-APS
Service Manual
LWU650-APS / LWU530-APS
PCB is lower
Rib
than the rib by
1.2mm or more.
Sensor PCB
PCB is higher
Rib
than the rib.
Sensor PCB
PCB sticks out,
or rotates and
sticks out.