Measuring variants
3.1 General requirements
Turning measurement - inside diameter (CYCLE974, CYCLE994) (Page 95)
Turning measurement - outside diameter (CYCLE974, CYCLE994) (Page 99)
3.1.4
Result parameters
Definition
Result parameters are measurement results provided by the measuring cycles.
Parameters
_OVR[ ]
_OVI[ ]
Call
The result parameters of the measuring cycles are saved in the channel-specific user variables.
These can be called from the operating area as follows:
Note
If not only SGUD variables exist, the "GUD selection" softkey must be used to select "SGUD".
Measuring variants
Which result parameters are output from the measuring cycles, is described in the individual
measuring variants.
For workpiece measurement with tool offset or offset in the WO, several measuring variants
also supply result parameters, see Section Additional result parameters (Page 342).
80
Type
Meaning
REAL
Result parameter - real number:
Setpoint values, actual values, differences, offset values, etc.
INTEGER
Result parameter - integer
1. Press the "Parameter" softkey.
3. Press the "User variable" softkey.
The result parameters _OVR[ ] and _OVI[ ] are displayed in the
"Channel-specific user variables" window.
2. Press the "Channel GUD" softkey.
Programming Manual, 12/2017, 6FC5398-4BP40-6BA1
Measuring cycles