Calibrate Probe - Radius On Surface (Cycle973) - Siemens SINUMERIK 840D sl Programming Manual

Measuring cycles
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

3.2.3

Calibrate probe - radius on surface (CYCLE973)

Function
Only applies on turning machines without the milling technology.
With this measuring version, the radius of a workpiece probe with cutting edge positions SL=5
to 8 can be calibrated on a surface. The trigger points of the probe are determined.
The calibration surface is workpiece-related. It is only possible to calibrate in the selected axis
and direction, which are perpendicular to this calibration surface.
Measuring principle
The determined switching position of the workpiece probe in the parameterized axis and
direction, is calculated with the setpoint of the reference surface and from this the
corresponding trigger point determined.
If no alarms occur, the trigger values are entered into the selected calibration data set of the
workpiece probe.
The probe travels in the measuring direction to the reference surface (e.g. workpiece)
Figure 3-2
Requirements
● The surface must be in parallel to an axis of the workpiece coordinate system (WCS).
● The calibration surface must have a low surface roughness.
● The workpiece probe is called as tool with tool offset.
● 580 must be declared as the probe type.
Measuring cycles
Programming Manual, 12/2017, 6FC5398-4BP40-6BA1
Calibrate: radius at the surface (CYCLE973), example G18, SL=8
Measuring variants
3.2 Measure workpiece (turning)
85

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840de sl

Table of Contents