11 Programming of Cycles
11.6 Data transfer: System memory into R parameter
The contents of the R parameter is to be interpreted as in the following example:
R50 = 3004 . 01
Channel number
Alarm number
Main group 3/subgroup d: Read alarm indications in R parameters
@ 3d0 <Var>
With this command the number of entered NC alarms is read in the variable <Var>.
Example:
@ 3d0
R51
11.7

Data transfer: R parameter into system memory

The main group 4 is organized as follows:
@ 4
x
y
Three-digit @ code
Special function
0: Machine data
1: Setting data
2: Tool offsets
3: Zero offsets
4: Programmed set values
e: System cells
4: Main group 4
All @ commands in this main group have <Value> as the last notation. This defines the
numerical value to be transferred, directly with a constant or indirectly via an R parameter or a
pointer.
Note:
@714 must be programmed prior to using the subgroups 0, 1, 2 and 3.
11–26
The number of present NC alarms is read in R51.