11 Programming of Cycles
11.6 Data transfer: System memory into R parameter
Example:
@3b0
R60 = (1, 3, 2, 2, 10);
@3b1 <Var> <Value 1> <Value 2> <Value 3> <Value 4> <Value 5>
The BCD value of the defined data words in the PLC is read in the parameter defined with
<Var>. The PLC number is defined by <Value 1>, the number of the DB or DX by
<Value 2>, the data word number by <Value 3>, the number of data words by <Value
4> and the dimension identifier by <Value 5>.
Depending on the defined number of data words <Value 4>, the read operation is either
serial or parallel:
<Value 4>
BCD
1
One data word is read, dimension identifier <Value 5> is meaningless.
2
Two data words are read in parallel. Dimension identifier <Value 5> is meaningless.
3
Three data words are read in serial. Dimension identifier <Value 5> specifies how BCD value is
to be read.
Definition of dimension identifier <Value 5>:
<Value 5>
BCD
100
Value without decimal point
101
Value with decimal point
102
1 place after the decimal point
103
2 places after the decimal point
104
3 places after the decimal point
105
4 places after the decimal point
106
5 places after the decimal point
107
6 places after the decimal point
108
7 places after the decimal point
109
8 places after the decimal point
Example:
@3b1
R51
K1
K2
@3b2 <Var> <Value 1> <Value 2> <Value 3>
The floating-point value of the defined data words in the PLC is read in the parameter
defined with <Var>. Two data words are always read in serially in the PLC. The PLC
11–24
The fixed-point value of the defined double word is
read in R60.
K10
K100
The BCD value of the defined double word is
read in R51.
© Siemens AG 1991 All Rights Reserved