11 Programming of Cycles
11.5 Data transfer, general
Main group 2/subgroup 0: Data transfer R parameter/R parameter
@200 <Var>
The value of the R parameter defined with the notation <Var> is deleted.
@201 <Var> <Wert>
The numerical value defined in < Value > is loaded in the R parameter defined in
<Var>.
@202 <Var 1> <Var 2>
The contents of the two R parameters defined in <Var1> and <Var 2> are exchanged.
@203 <Var 1> <Var 2> <Const>
A bit is read from the bit pattern.
Main group 2/subgroup 1:
@210 <Wert 3> <Wert 4>
Delete input buffer.
<Value 3>
start address
<Value 4>
end address
@211 <Var> <Wert 1>
The R parameter <Var> is loaded with the contents of the input buffer cell <Value1>.
Example:
@211 R50 K101
@212 <Wert 1> <Wert>
The input buffer cell <value 1> is loaded with the numeric quantity <value>.
Example:
@212 K102 K5
11–12
Data transfer R parameter/input buffer for
numerical variables
The contents of the input buffer cell 101 is read into parameter
R50.
The value 5 is written in the input buffer cell 102.