05.91
Note:
The following procedure is being determined for reading out the identifier:
Identifier: ... (
1.
Read left bracket:
R
+1 =
y
R
+5 =
y
2.
Read marking number
R
+1 =
y
R
+5 =
y
3.
Read right bracket:
R
+1 =
y
R
+5 =
y
Example: @f22 in the case of a block with marking
The following block is assumed:
a)
Word two is to be read by means of @f22.
After execution, the following values are contained in the output R parameters
R
: 0
y
R
+1
: 88 ("X")
y
R
+2
: 0
y
R
+3
: 0
y
R
+4
: 0
y
R
+5
: 100
y
b)
Word five is to be read by means of @f22.
R
: 0
y
R
+1
: 35 ("#")
y
R
+2
: 0
y
R
+3
: 0
y
R
+4
: 0
y
R
+5
: 10
y
© Siemens AG 1991 All Rights Reserved
SINUMERIK 880, (PG)
#05#
) L
F
40
=
(
32
=
35
=
#
5
=
05
41
=
)
32
=
N50
G03
X100
Y50
No error
Address letter
Extended address No
No extended address
Operator not available
Value
No error
Address letter
Extended address No
No extended address
Operator not available
Value
6ZB5 410-0HD02
11 Programming of Cycles
11.11 Part program handling
(#10#)
L F
11–61