Siemens SINUMERIK 880 Programming Manual page 203

Hide thumbs Also See for SINUMERIK 880:
Table of Contents

Advertisement

11 Programming of Cycles
11.6 Data transfer: System memory into R parameter
Main group 3/subgroup 3:
@330 <Var> <Value 1> <Value 2> <Value 3>
The notations <Value 1> to <Value 3> must be allocated as follows:
<Value 1>
Group of settable zero offsets (G54 = 1 to G57 = 4)
<Value 2>
Number of axes
<Value 3>
Coarse and fine value (0 or 1)
Example:
@330
R81
K1
@331 <Var> <Value 1> <Value 2>
Where:
<Value 1>
Group of programmable additive zero offsets (G58 = 1 and G59 = 2)
<Value 2>
Number of axis
@332 <Var> <Value 2>
The number of the axis of the external zero offset input from the PLC is defined in
<Value 2>.
@333 <Var> <Value 2>
The number of the axis of the PRESET offset is defined in <Value 2>.
@334 <Var> <Value 2>
The number of the axis of the DRF offset is defined in <Value 2>.
@336 <Var> <Value 2>
The number of the axis of the cumulative offset is defined in <Value 2>. The cumulative
offset contains:
• the selected settable zero offsets
• the programmable additive zero offset
• the external zero offset
• the selected tool offset.
PRESET and DRF offsets are not considered.
@337 <Var> <Value 1> <Value 2> <Value 3>
The rotation angle of the settable coordinate rotations can be read into parameter <Var>.
The notations <Value 1> to <Value 3> must be allocated as follows:
<Value 1>
Number of channel (0 = own channel)
<Value 2>
Group of settable coordinate rotations (G54 = 1 to G57 = 4)
<Value 3>
Number of angle (at present = 1)
11–16
Transfer zero offsets into R parameter
K2
K0
The coarse value of the first settable zero offset (G54)
of the second axis is read into parameter R81.
© Siemens AG 1991 All Rights Reserved
05.91
6ZB5 410-0HD02
SINUMERIK 880, (PG)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sw 6Sinumerik 880 ga2Sw 1

Table of Contents