Analog Devices ADuCM310 Hardware Reference Manual page 146

Table of Contents

Advertisement

UG-549
Bits
Bit Name
6
HFM
[5:0]
DIV
SPI Configuration Register
Address: 0x40030010, Reset: 0x0000, Name: SPI1CON
Table 210. Bit Descriptions for SPI1CON
Bits
Bit Name
[15:14]
MOD
13
TFLUSH
12
RFLUSH
11
CON
10
LOOPBACK
9
OEN
8
RXOF
7
ZEN
Description
High frequency mode. This bit is used for applications using high frequency
where the pad introduces a significant delay on the SCL, which can cause a
significant enough difference between the serial clock and the data being
received on the Rx shift register. In this mode, the Rx shift register is clocked
by SCL instead of UCLK.
SPI clock divider. DIV is the factor that divides HCLK to generate the serial clock.
Description
SPI IRQ mode bits. These bits configure when the Tx/Rx interrupts occur in
a transfer. For DMA Rx transfer, these bits must be 00.
00: Tx interrupt occurs when 1 byte is transferred. Rx interrupt occurs when
1 or more bytes are received into the FIFO.
01: Tx interrupt occurs when 2 bytes are transferred. Rx interrupt occurs
when 2 or more bytes are received into the FIFO.
10: Tx interrupt occurs when 3 bytes are transferred. Rx interrupt occurs
when 3 or more bytes are received into the FIFO.
11: Tx interrupt occurs when 4 bytes are transferred. Rx interrupt occurs
when the Rx FIFO is full, or 4 bytes present.
SPI Tx FIFO flush enable.
0: clear this bit to disable Tx FIFO flushing.
1: set this bit to flush the Tx FIFO. This bit does not clear itself and must be
toggled if a single flush is required. If this bit is left high, either the last
transmitted value or 0x00 is transmitted depending on the ZEN bit. Any
writes to the Tx FIFO are ignored while this bit is set.
SPI Rx FIFO flush enable.
0: clear this bit to disable Rx FIFO flushing.
1: set this bit to flush the Rx FIFO. This bit does not clear itself and must be
toggled if a single flush is required. If this bit is set, all incoming data is
ignored and no interrupts are generated. If set and TIM = 0, a read of the
Rx FIFO initiates a transfer.
Continuous transfer enable.
0: DIS. Cleared by user to disable continuous transfer. Each transfer
consists of a single 8-bit serial transfer. If valid data exists in the SPI1TX
register, a new transfer is initiated after a stall period of 1 serial clock cycle.
1: EN. Set by user to enable continuous transfer. In master mode, the
transfer continues until no valid data is available in the Tx register. CS is
asserted and remains asserted for the duration of each 8-bit serial transfer
until Tx is empty.
Loopback enable.
0: cleared by user to be in normal mode.
1: set by user to connect MISO to MOSI and test software.
Slave MISO output enable.
0: clear this bit to disable the output driver on the MISO pin. The MISO pin
is open-circuit when this bit is clear.
1: set this bit for MISO to operate as normal.
SPIRX overflow overwrite enable.
0: cleared by user; the new serial byte received is discarded.
1: set by user; the valid data in the Rx register is overwritten by the new
serial byte received.
Transmit zeros enable.
0: clear this bit to transmit the last transmitted value when there is no valid
data in the Tx FIFO.
1: set this bit to transmit 0x00 when there is no valid data in the Tx FIFO.
Rev. C | Page 146 of 192
ADuCM310 Hardware Reference Manual
Reset
Access
0x0
RW
0x0
RW
Reset
Access
0x0
RW
0x0
RW
0x0
RW
0x0
RW
0x0
RW
0x0
RW
0x0
RW
0x0
RW