ADuCM310 Hardware Reference Manual
Capture Event Function
There are a number of interrupt events that can be captured by the general-purpose timers. These events are shown in Table 225. Any of
the events associated with a general-purpose timer can cause a capture of the 16-bit TxVAL register into the 16-bit TxCAP register.
TxCON has a 4-bit field selecting which of the events to capture.
When the selected interrupt event occurs, the TxVAL register is copied into the TxCAP register. TxSTA[1] is set, indicating that a capture
event is pending. The bit is cleared by writing 1 to TxCLRI[1]. The TxCAP register also holds its value and cannot be overwritten until a 1
is written to TxCLRI[1].
Table 225. Capture Event Function
Event Select Bits
(EVENT Bits in TxCON Register,
TxCON[11:8])
0000
0001
0010
0011
0100
0101
0110
0111
1000
1001
1010
1011
1100
1101
1110
1111
Timer 0 Capture Source
Wake-Up Timer
External Interrupt 0
External Interrupt 1
External Interrupt 2
External Interrupt 3
External Interrupt 4
External Interrupt 5
External Interrupt 6
External Interrupt 7
External Interrupt 8
Watchdog timer
Reserved
Reserved
Low Voltage Analog Die Interrupt 0
Reserved
General-Purpose Timer 1
Rev. C | Page 159 of 192
Timer 1 Capture Source
External Interrupt 4
External Interrupt 5
External Interrupt 6
Flash controller
UART
SPI0
PLA 0
PLA 1
DMA Error
DMA Done (Any)
Reserved
Reserved
Reserved
I
2
C1 slave
2
I
C1 master
General-Purpose Timer 2
UG-549
Timer 2 Capture Source
External Interrupt 7
External Interrupt 8
SPI1
2
I
C0 slave
I
2
C0 master
PLA 2
PLA 3
PWM trip
PWM 0
PWM 1
PWM 2
PWM 3
Low Voltage Analog Die Interrupt 1
External Interrupt 0
External Interrupt 1
General-Purpose Timer 1