Collet Aligning Screw Replacement - Sharp V-1 General & Electrics Manual

Vertical mill
Table of Contents

Advertisement

SHARP

7.6 COLLET ALIGNING SCREW REPLACEMENT

7.6.1 FOR #30
(1) Use felt pen, mark reference line on quill and nose cap 'B'.
(2) Remove set screw 'A'.
(3) Unscrew nose cap 'B'.
(4) Replace nose cap 'B';
check felt pen markings for correct alignment.
(5) Replace set screw 'A'
Caution do not overtighten as this will cause distortion.
(6) Check gap 'E'. (.003"=.08mm).
V-1 KNEE MILL GENERAL MANUAL
CH7-9