7.10.14.1.2 Metering controller

With the function "Metering controller", the metered quantity is measured via the oval gear
meter connected for metering monitoring. If the measured flow rate deviates from the
metering rate set at the pump, the metering speed of the pump is automatically adjusted
via a control algorithm.
The menu item "Metering controller" can only be selected if an oval gear
meter is connected to the input provided for this purpose (see
6.4 'Electrical installation' on page 56).
Fig. 71: Configuration: Metering controller
Factory setting: Without metering controller
[Select Metering controller] :
1.
[Call up the Main menu] :
2.
[Select Configuration] :
3.
Use the scrollbar to scroll to the [Oval gear meter] menu item.
4.
[Select Oval gear meter] .
ð Screen switches to the [selection Oval gear meter].
5.
[Select Metering controller] .
ð Screen change for the setting: [Metering controller]
6.
If required, select the selection field 'With metering controller' .
ð The selection field 'With metering controller' is marked
7.
Press the
ð The setting is saved, and the screen switches back to the configuration overview.
8.
By pressing the
9.
By pressing the
417102276 Rev. 5-02.2020
3
4
Ä Chapter 7.7 'Main menu' on page 73
Ä Chapter 7.10 'Overview - Configuration' on page 92
button.
button, you can return to the [main menu].
button, you can return to the [operating display].