Repair / Replacing The Control Unit; Remove The Bluetooth Pcb; Create A Backup And Import Back Onto The New Control Unit Following Conversion - Ecolab EcoAdd Series Operating Instructions Manual

Dynamic pump
Table of Contents

Advertisement

Available languages

Available languages

13.3

Repair / replacing the control unit

13.3.1

Remove the Bluetooth PCB

Fig. 107: 417102276_13-4
1.
Unfasten cover screws (x 4) using a Torx wrench (TX25).
2.
Remove the lid forwards.
3.
Remove the Bluetooth PCB from the slot.
4.
Fit the Bluetooth PCB into the new control unit.
13.3.2

Create a backup and import back onto the new control unit following conversion

See also chapter
on page 130
2
1.
Press the Menu button
2.
Insert the USB stick containing the configuration into the USB port on the pump.
3.
Select Configuration [from the] [main menu] .
4.
[Select USB export] .
ð An export file (*.PAR) is copied to the USB stick.
5.
Press the
6.
Remove the USB stick from the USB port.
7.
Switch off the pump and disconnect from the mains.
8.
Exchange the control unit
as described.
9.
Import the configuration back to the new control unit.
1
2
Ä Chapter 7.14 'Import and export functions'
1
3
.
button.
Ä Chapter 13.1.1 'Rotating the control unit' on page 176
179
Conversion, upgrade, repair
3
4
417102276 Rev. 5-02.2020