6.3.2.3 Pipe and hose connection with attachment nipple and hose clamp

1
2
3
4
5
Fig. 13: Pipe and hose connection with attachment nipple and hose clamp
A
Detail/Section: Illustration of individual part
1
Hose
2
Swivel nut
3
Cone
4
O-Ring
1.
Cut hose (Pos. 1) straight.
2.
Push the swivel nut (pos. 2) over the hose (pos. 1).
3.
Push the hose clamp (6) over the hose (1).
4.
Push the hose (pos. 1) onto the tapered part (pos. 3) up to the stop collar (detail A1).
5.
Place an O-ring (pos. 4) in the groove of the suction or pressure valve (pos. 5).
6.
Tighten the union nut (2) (detail B1).
7.
Push the hose clamp (6) downward and tighten (detail B1).
A1
6
B1
53
Mounting and installation
5
Suction valve, pressure valve
6
Hose clip
A1 Pipe or Hose plugged on
B1 Valve connection: Target state after assembly