Electrical Installation - Ecolab EcoAdd Series Operating Instructions Manual

Dynamic pump
Table of Contents

Advertisement

Available languages

Available languages

Mounting and installation
6.4

Electrical installation

Personnel:
DANGER!
Risk of electric shock
All electrical work may only be carried out by trained and authorised skilled
personnel in accordance with the currently applicable CE directives or the
relevant local regulations.
Pay attention to disconnect the power supply immediately and to secure
against accidental switch-on!
Fig. 15: Electrical installation 'EcoAdd'
1.
Remove all four housing screws.
2.
Remove the front cover.
3.
To connect additional external enable signals, route the connector lines through the
clamping cube.
4.
Complete electrical installation
5.
After electrical installation has been completed, fit the cover back onto the housing.
417102276 Rev. 5-02.2020
n
Qualified electrician
1
The mains cable is already installed at the factory.
(
Ä Chapter 6.4.2 'Mains supply connection' on page 58).
Ä Chapter 6.4 'Electrical installation' on page 56.
Permissible external cable Ø for connecting the inputs/outputs:
AD Ø = 5.1-5.7 mm. LIYY 4x0.5; LIYY 5x0.34; LYCY 2x0.34
Permissible cables: Oilflex 4x0.5
IP65 is applicable only when the specified cable is being used.
NOTICE!
Make sure that the seal is free of dirt to ensure that it seals the system
properly. Tighten all four housing screws (pos. 1) "by hand" (1 Nm)
2
56