Access Code - Ecolab EcoAdd Series Operating Instructions Manual

Dynamic pump
Table of Contents

Advertisement

Available languages

Available languages

7.10.4

Access code

Here the operation of the pump can be secured via access codes.
2 access levels with different access authorisations can be set.
CAUTION!
To exclude the possibility of the pump being used improperly and / or of the
system parameters being adjusted inadvertently, the pump software can
and should be protected by the integrated multi-stage [access code] .
The safety setting is not activated when the pump is first started!
During the initial configuration of the pump, we strongly recommend
enabling the [access code] 'Administrator (A)' and 'Operator (O)' and
providing the [access code] only to the authorised personnel!
User with the [access code] 'Operator (O)' have fewer authorisations in the setting
options. The [access code] for 'Administrator (A)' has complete access to all the functions
of the 'EcoAdd' pump.
– In the [Configuration] the [access code] of 'the Administrator (A)' level is
entered first, followed by that of the 'Operator (O)' level.
– If the [access code] of 'Administrator (A)' is not set, then the setting of
[access code] of 'Operator (O)' is not displayed.
Thus the pump does not have any protection against access!
– After setting the [access code] of 'Administrator (A)' the [access code]
of 'Operator (O)' can be set or also omitted.
– If no [access code] of 'Operator (O)' is specified, then for each setting
the [access code] of 'Administrator (A)' is required.
– If both [access codes] are present, there is a reduction in the
authorisations by querying the [access code] of 'Operator (O)' .
– When using only one [access code], general unrestricted access
( 'Administrator (A)' ) is guaranteed!
Overview of access authorisations:
= Operator,
= Administrator
Restrictions for users with [access code] 'Operator (O)' :
n
Changing the [access code] is not possible.
n
Changing the [metering mode] is not possible.
n
Changing the [operating mode] is not possible.
n
Changing the [configuration] is not possible.
n
Export and import parameters via USB is not possible.
n
No authorisation to change the metering capacity.
n
No authorisation to change the concentration.
No authorisation to change the metering capacity per
n
pulse.
n
No authorisation to carry out pump servicing.
97
Control / Software
417102276 Rev. 5-02.2020