Install Fittings in the Flow Switch
Fittings and Transducers Installed in the Flow Switch
FIGURE 1.
Install -6 ORFS (M) to -6 SAE O-ring (M) straight adapter fittings (P/N 333-0012-084) in the ends of the flow
1.
switch (P/N 334-0003-085), one in an A port and one in a B port.
Install pressure transducers into the remaining A and B ports.
2.
Note:
It makes no difference in which port the adapter fittings and pressure transducers are installed as
long as one of each is installed in an A port and the other is installed in a B port.
Mount the SmarTrax Valve and Flow Switch
Valve Mounting Location
FIGURE 2.
Identify the SmarTrax valve (P/N 334-0003-088) mounting location above the machine's left-front axle.
1.
Remove the machine's existing bolts shown in Figure 2.
2.
Manual No. 016-5032-023 Rev. A
Hydraulic System Installation