Page 1
Case IH Patriot 4430, Model Year 2012 SmarTrax™ Installation Manual P/N 016-5032-082 Rev A 09/15 E22879 Copyright 2014, 2015...
Page 2
GPS, GNSS, SBAS, etc.). Therefore, Raven Industries cannot guarantee the accuracy, integrity, continuity, or availability of these services and cannot guarantee the ability to use Raven systems, or products used as components of systems, which rely upon the reception of these signals or availability of these services.
..................10 Install Fittings on the Flow Switch ................... 11 Mount the SmarTrax Valve ...................... 11 Install the SmarTrax Valve Mounting Bracket ..............11 Mount the SmarTrax Valve ....................12 Install the Pressure Hose ......................12 Install the Tank Hose .......................
Page 4
Table of Contents Case IH Patriot 4430, Model Year 2012 SmarTrax™ Installation Manual...
Ensure SmarTrax is disabled prior to starting any maintenance work on SmarTrax or the machine. WARNING • When starting the machine for the first time after installing SmarTrax, be sure that all persons stand clear in case a hose has not been properly tightened. •...
CAUTION Hydraulic Safety • Raven Industries recommends that appropriate protective equipment be worn at all times when working on the hydraulic system. • Never attempt to open or work on a hydraulic system with the equipment running. Care should always be taken when opening a system that has been previously pressurized.
Preparing for Installation Before installing the SmarTrax system, park the machine where the ground is level, clean, and dry. Turn off the machine and leave it turned off for the duration of the installation process. Bleed pressure from the hydraulic system by loosening the hydraulic fittings slowly, where applicable.
Recommendations Raven Industries recommends the following best practices when installing or operating the SmarTrax system for the first time, at the start of the season, or when moving the SmarTrax system to another machine: • Install the GPS antenna in the recommended location. Refer to the following table for the machine-specific antenna mounting location.
This section contains a list of the components that are included in the SmarTrax kit. Before beginning the SmarTrax installation, compare the items in the kit with the components on this list. If you have questions about the kit, contact your Raven dealer.
Page 10
Screw - 1/4”-20 x 2” Socket Head 311-0050-109 Bolt - 5/16” Hex Head 311-0052-104 Nut - 1/4”-20 Hex 312-1001-074 Nut - 3/8”-16 Zinc Flanged Lock 312-1001-164 Nut - M6 Lock 312-4000-207 Case IH Patriot 4430, Model Year 2012 SmarTrax™ Installation Manual...
WARNING Hydraulics are under pressure. Care should always be taken with a system that has been pressurized. Before beginning the SmarTrax hydraulic installation, turn off the machine and relieve pressure by turning the steering wheel left and right. When disconnecting or purging hydraulic hoses, be aware that the hydraulic fluid within the machine’s system may be extremely hot...
Install Fittings on the SmarTrax Valve Before mounting the SmarTrax valve (P/N 334-0003-088) on the machine, install the proper fittings in the valve. This prepares the valve for installation and simplifies the hose connection process later in the procedure.
(P/N 334-003-085). Install the pressure transducers in Ports A1 and B1 of the flow switch. Mount the SmarTrax Valve Install the SmarTrax Valve Mounting Bracket Valve Mounting Location FIGURE 3. Remove the bolts used to secure the machine’s radar bracket (beneath the cab).
SmarTrax Valve Installed on Mounting Bracket FIGURE 5. Mount the SmarTrax valve (P/N 334-0003-088) to the valve mounting bracket (P/N 107-0171-705) using four 5/16” hex bolts (P/N 311-0052-104) and four 5/16” lock washers (P/N 313-1000-019). Mount the flow switch (P/N 334-0003-085) to the valve mounting bracket using two 1/4”-20 x 2” screws (P/N 311-0050-109), two 1/4”...
Install the 90° end of the supplied hydraulic hose (P/N 214-1000-657) on the 90° end of the installed tee fitting. Connect the straight end of the installed hydraulic hose to Port P of the SmarTrax valve. Install the Tank Hose Locate the machine’s steel tank line.
Install the -8 end of the supplied hydraulic hose (P/N 214-1000-658) on the 90° end of the installed tee fitting. Connect the other end of the installed hydraulic hose to Port T of the SmarTrax valve. Install the Left and Right Steering Hoses Locate and disconnect the machine’s left steering hose from the left steering cylinder.
Page 19
Install the 90° end of the supplied hydraulic hose (P/N 214-1000-659) on the 90° end of the installed tee fitting. Connect the straight end of the installed hydraulic hose to Port B of the SmarTrax valve (P/N 334-0003- 088). Manual No. 016-5032-082 Rev. A...
C ab Component CHAPTER C h a p t e r 4 Installation Prepare the Cab for Installation Instructional Seat Mounting Screws FIGURE 1. Uninstall the instructional seat cushion by removing the screws that secure it to the frame. Remove any contents from under the instructional seat. Floor Mat Removed from Cab FIGURE 2.
Node Mounted to Mounting Plate FIGURE 4. Mount the SmarTrax node (P/N 063-0173-228) to the node mounting plate (P/N 107-0172-084) using three 3/8”-16 zinc flanged lock nuts (P/N 312-1001-164). Place the node in the instructional seat compartment so the connectors face the operator’s seat.
Mounting Tabs When choosing the location for the SmarTrax node, consider the following points: • Mount the SmarTrax node inside the machine’s cab on a flat, level surface for proper performance and cable connection. • One of the six numbered direction arrows on the node must be oriented in the direction of forward vehicle travel, one arrow pointing straight up, and two of the arrows parallel to the ground.
Using the holes in the foot switch as a template, drill holes in the floor of the cab. Secure the foot switch to the floor by installing the supplied screws in each of the mounting holes. Route the foot switch cable connector toward the SmarTrax node (P/N 063-0173-228) mounting location. Install the Node Harness Node Cable Installed on Node FIGURE 7.
Page 25
Cab Component Installation Locate the ENABLE connector on the node harness and connect it to the foot switch cable connector. Route the node cable into the fuse box and behind the operator’s seat. CAN Connector Installed on Machine’s CAN System FIGURE 8.
Page 26
High current power, which is used to run the steering operations, should be connected to a power source separate from logic power, which is used to facilitate processing and communication between the node and the console. Case IH Patriot 4430, Model Year 2012 SmarTrax™ Installation Manual...
Cab Component Installation Install the Valve Harness Valve Cable Routed Through Access Point FIGURE 12. Route the valve cable into the cab from the foam access point under the convenience tray on the right side of the seat. Remove the vent plate behind the operator’s seat. Valve Cable Connected to Node Cable FIGURE 13.
Page 28
Note: These connections can be plugged into either transducer. Plug the VALVE connector from the valve cable into the open port at the end of the SmarTrax valve (P/N 334-0003-088). Case IH Patriot 4430, Model Year 2012 SmarTrax™ Installation Manual...
Turn the machine’s wheels fully from side to side repeatedly to remove air from the hydraulic system. Note: During the SmarTrax system installation, whenever the hydraulic system is purged for maintenance, or when fittings are loosened or disconnected, air is introduced into the lines of the hydraulic system.
Raven console. Note: If there are issues with the SmarTrax system, turn off the machine and correct them immediately. For additional assistance, refer to the SmarTrax and SmartSteer Calibration & Operation Manual (P/N 016-0171-277) or contact your local Raven dealer.
Page 33
System Diagrams 25 Hydraulic System Installation Hydraulic System Diagram 16 Installing Fittings on the Flow Switch 11 Installing Fittings on the SmarTrax Valve 10 Installing the Left and Right Steering Hoses 14 Installing the Pressure Hose 12 Installing the Tank Hose 13...
Page 34
Index Case IH Patriot 4430, Model Year 2012 SmarTrax™ Installation Manual...
Page 37
Bring the defective part and proof of purchase to your Raven dealer. If the dealer approves the warranty claim, the dealer will process the claim and send it to Raven Industries for final approval. The freight cost to Raven Industries will be the customer’s responsibility. The Return...
Page 38
How Can I Get Service? Bring the defective part and proof of purchase to your Raven dealer. If the dealer approves the warranty claim, the dealer will process the claim and send it to Raven Industries for final approval.
Need help?
Do you have a question about the SmarTrax and is the answer not in the manual?
Questions and answers