Install the Override Flow Switch
Fittings and Transducers Installed in the Flow Switch
FIGURE 7.
Install the
ORFS (M) to
-6
1.
334-0003-085), one in an A port and one in a B port.
Install pressure transducers into the remaining A and B ports.
2.
Note:
It makes no difference in which ports the adapter fittings and pressure transducers are installed as
long as one of each is installed in an A port and the other is installed in a B port.
Flow Switch Mounted on the Machine
FIGURE 8.
Axle Mounting Location
(Bottom View)
Mount the flow switch to the valve mounting bracket using the supplied M8 hex head bolt (P/N 311-0070-
3.
044) and the 5/16" lock washer (P/N 313-1000-019).
Note:
The existing bolt in the selected mounting location will need to be removed.
Manual No. 016-5032-004
SAE O-Ring (M) straight adapter fittings in the ends of the flow switch (P/N
-6
Valve
Mounting
Bolts
Hydraulic System Installation
Cab Mounting Location
(Left Side View)
Front of Machine
13