TANDBERG Codec C60 and Codec C40
Contents
Contents
Introduction
Introduction
The System Unit commands,
cont...
xCommand SystemUnit ConfigurationProfile List
List configuration profiles that has been stored in the system.
Parameters:
No parameters.
Example:
xCommand SystemUnit ConfigurationProfile List
*r ConfigurationProfileListResult (status=OK):
Profile: My _ ConfigurationProfile _ 1
Profile: My _ ConfigurationProfile _ 2
** end
xCommand SystemUnit ConfigurationProfile Change
Select a previously saved configuration profile. Will be active after next system boot. Can be cancelled
before the reboot, by the xCommand SystemUnit ConfigurationProfile CancelChange command.
Parameters:
Name(r): <S: 0, 255>
Example:
xCommand SystemUnit ConfigurationProfile Change Name: "My _
ConfigurationProfile _ 1"
*r ConfigurationProfileChangeResult (status=OK):
Warning: New configuration profile will be active after next boot.
** end
xCommand SystemUnit ConfigurationProfile CancelChange
Cancel the xCommand SystemUnit ConfigurationProfile Change command, that would otherwise take
effect after next system boot.
Parameters:
Name(r): <S: 0, 255>
Example:
xCommand SystemUnit ConfigurationProfile CancelChange Name: "My _
ConfigurationProfile _ 1"
*r ConfigurationProfileCancelChangeResult (status=OK):
** end
D14642.02—MAY 2010
About the API
About the API
xConfiguration
xConfiguration
xCommand
xCommand
xCommand
xStatus
xStatus
The System Unit commands,
cont...
xCommand SystemUnit ConfigurationProfile Remove
Delete a configuration profile that has been stored in the system.
Parameters:
Name(r): <S: 0, 255>
Example:
xCommand SystemUnit ConfigurationProfile Remove Name: "My _
ConfigurationProfile _ 1"
*r ConfigurationProfileRemoveResult (status=OK):
** end
xCommand SystemUnit FactoryReset
Reset the codec to factory default settings, followed by an automatic reboot of the codec.
The call logs will be deleted and all system parameters will be reset to default values. All files that have
been uploaded to the codec will be deleted. The Release key and Option key will not be affected.
Parameters:
Confirm(r): <Yes>
Example:
xCommand SystemUnit FactoryReset Confirm: Yes
*r FactoryResetConfirmResult (status=OK):
** end
80
API Guide
Appendices
Appendices
Contact us
Contact us
www.tandberg.com
Need help?
Do you have a question about the Codec C Series and is the answer not in the manual?