The Experimental menu
The Advanced configurations menu has an option called Experimental. The settings within this menu
can be used 'as is' and will not be fully documented.
xConfiguration Experimental Audio Input Microphone [1..2]/[1..4] Channel
NOTE! Codec C40 has two microphone connectors. Codec C60 has four microphone connectors.
Defines whether the signal from the microphone is a mono signal or part of a multichannel signal.
Value space: <Left/Right/Mono>
Left: The Audio Microphone input signal is the left channel of a stereo signal.
Right: The Audio Microphone input signal is the right channel of a stereo signal.
Mono: The Audio Microphone input signal is a mono signal.
Example:
xConfiguration Experimental Audio Input
xConfiguration Experimental Audio Input Microphone [1..4] EchoControl
HighPassFilter
Value space: <On/Off>
xConfiguration Experimental CapsetFilter
Value space: <S: 0, 32>
xConfiguration Experimental Conference [1..1] PacketLossResilience
Value space: <On/Off>
xConfiguration Experimental CustomSoftbuttons State [1..2] Softbutton [1..5] Type
Value space: <NotSet/MainSource/PresentationSource/CameraPreset/Actions/SpeedDial>
xConfiguration Experimental CustomSoftbuttons State [1..2] Softbutton [1..5] Value
Value space: <S: 0, 255>
xConfiguration Experimental SoftwareUpgrade Mode
Value space: <Auto/Manual>
xConfiguration Experimental SoftwareUpgrade ServerAddress
Value space: <S: 0, 255>
D14642.02—MAY 2010
xConfiguration
About the API
About the API
xConfiguration
xConfiguration
NOTE!
The Experimenal menu WILL change.
Microphone 1 Channel: Left
xCommand
xCommand
xStatus