PLC Commissioning
13.3.5 Setting up the motion axis
The following steps show how to basically setup the motion axis.
1. Set axis unit:
Choose Unit Conversion Settings in the Edit-Window of your axis and set Unit to "mm".
2. Set axis scaling:
Set Travel Distance to 10'000:1.
3. Set axis velocity limits:
Choose Operation Settings and set your desired values into Maximum velocity fields.
4. Download program to your PLC:
Rebuild Controller and then go Online and Transfer
NTI AG / LinMot