PLC Commissioning

8.3 PLC Setup

8.3.1 EtherCAT Device Description File XML

The EtherCAT device description file (XML) is located by default in the LinMot-Talk installation path:
C:\Program Files (x86)\LinMot\LinMot-Talk X.X Build XXXXXXXX\Firmware\Interfaces\EtherCAT_SoE\XML
Copy this file to your local TwinCAT installation path:
C:\TwinCAT\Io\EtherCAT\
C:\TwinCAT\3.1\Config\Io\EtherCAT
Note: You may have to restart the developing environment to have the new XML file to be recognized.

8.3.2 Scanning the EtherCAT for new Devices

Follow these steps to add the LinMot drive to your Beckhoff PLC.
1. Restart your PLC into the Config Mode to be able to scan for attached devices.
2. Right-Click in the project tree on Devices and select Scan
Select and insert the found EtherCAT master (e.g. Device 3 (EtherCAT)).
You can now directly scan for boxes. If you select yes, then skip the next step.
3. Right-Click on your EtherCAT master (the one found in the previous step) and select Scan
NTI AG / LinMot
(for TwinCAT 2)
(for TwinCAT 3)