12.12 Parameter Access

12.12.1 Parameter access by LMcf_ParaAccess function block

Every parameter and variable in a LinMot system has its own UPID (Unique Parameter ID).
Read and write access is possible using the LMcf_ParaAccess function block from the library LinMot.
Supported Modes
Value
Used Inputs
0
UPIDIn
1
UPIDIn
2
UPIDIn, ValueIn
3
UPIDIn, ValueIn
4
UPIDIn, ValueIn
5
UPIDIn
6
UPIDIn
7
UPIDIn
Attention ROM Access:
Intense use of writing into the ROM memory can reduce the life-time of the drive memory!
More details can be found in the Drive Configuration Over Fieldbus (0185-1074) user manual
> see chapter Documentation / User Manuals
Note:
Further documentation about this function block can be found in the LinMot library manual.
See chapter 12.1.
Page 178 of 205
Description
Read ROM Value of Parameter by UPID
Read RAM Value of Parameter by UPID
Write ROM Value of Parameter by UPID
Write RAM Value of Parameter by UPID
Write RAM and ROM Value of Parameter by U
Get minimal Value of Parameter by UPID
Get maximal Value of Parameter by UPID
Get default Value of Parameter by UPID
PLC Commissioning