11.3.3 Check EoE settings
On supported drives (C1250-..., C1450-... & E1450-...) please check the EoE (Ethernet over EtherCAT)
settings.
You can enable the Virtual Ethernet Port and assign an IP to be able to login over EtherCAT into the drive using
LinMot-Talk.
Be aware that the PLC must route the requests from LinMot-Talk over Ethernet to the EtherCAT network.
Note:
EoE can be used to login into the drive with LinMot-Talk directly over EtherCAT.
E.g. to change drive settings or for monitoring and tracing.
If not required, this feature can be disabled.
LinMot drives do NOT support the DHCP mode yet. A fix IP must be assigned or the EoE feature must
be completely disabled (disable Virtual Ethernet Port).
Page 140 of 205
PLC Commissioning
NTI AG / LinMot