AT commands

Special commands

The following commands are special commands.

WR (Write)

Writes parameter values to non-volatile memory so that parameter modifications persist through
subsequent resets.
Writing parameters to non-volatile memory does not apply the changes immediately. However, since
the device uses non-volatile memory to determine initial configuration following reset, the written
parameters are applied following a reset.
Note
Once you issue a WR command, do not send any additional characters to the device until after
you receive the OK response.
Parameter range
N/A
Default
N/A

RE (Restore Defaults)

Restore device parameters to factory defaults. Does not exit out of Command mode.
Parameter range
N/A
Default
N/A
FR (Software Reset)
Resets the device. The device responds immediately with an OK and performs a reset 100 ms later.
If you issue FR while the device is in Command Mode, the reset effectively exits Command mode.
Parameter range
N/A
Default
N/A

Networking and security commands

The following AT commands are networking and security commands.

C8 (802.15.4 Compatibility)

Sets or displays the operational compatibility with the Legacy 802.15.4 module (S1 hardware).