St Command; Special Commands - Digi XBee User Manual

Radio frequency (rf) module
Hide thumbs Also See for XBee:
Table of Contents

Advertisement

Commands
Parameter range
0 - 8 (3 is reserved)
Parameter
0
1
2
3
4
5
6
7
8
Default
0
Bytes returned
1

ST command

Sets or displays the amount of time (in milliseconds) that the device remains inactive before entering
Sleep mode. For example, if you set ST to 0x64 (100 decimal), the device enters Sleep mode after 10
seconds of inactivity (no transmitting or receiving).
You can only use this command if you use SM to select Cyclic Sleep or Serial Port Sleep mode settings;
see
SM (Sleep
Mode).
Binary command
0x02 (2 decimal)
Parameter range
(AT + 3) - 0x53E2 [x 100 ms]
Default
0x64 (10 seconds)
Bytes returned
2

Special commands

The following commands are special commands.
XBee®/XBee-PRO XTend Compatible (XTC) RF Module User Guide
Description
Disabled
Pin Sleep
Serial Port Sleep
[reserved]
Cyclic 1 second sleep (RF module wakes every 1.0 seconds)
Cyclic 2 second sleep
Cyclic 4 second sleep
Cyclic 8 second sleep
Cyclic 16 second sleep
Special commands
70

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xbee-pro xtc

Table of Contents