Special Commands; Fr (Software Reset); Re Command; Ac (Apply Changes) - Digi DigiMesh XBee S2C User Manual

Radio frequency (rf) modules
Hide thumbs Also See for DigiMesh XBee S2C:
Table of Contents

Advertisement

AT commands

Special commands

The following commands are special commands.

FR (Software Reset)

Resets the device. The device responds immediately with an OK and performs a reset 100 ms later.
If you issue FR while the device is in Command Mode, the reset effectively exits Command mode.
Parameter range
N/A
Default
N/A

RE command

Restore device parameters to factory defaults.
Parameter range
N/A
Default
N/A

AC (Apply Changes)

Immediately applies new settings without exiting Command mode.
Parameter range
N/A
Default
N/A

WR command

Writes parameter values to non-volatile memory so that parameter modifications persist through
subsequent resets.
Writing parameters to non-volatile memory does not apply the changes immediately. However, since
the device uses non-volatile memory to determine initial configuration following reset, the written
parameters are applied following a reset.
Note
Once you issue a WR command, do not send any additional characters to the device until after
you receive the OK response.
Parameter range
N/A
Default
N/A
XBee S2C DigiMesh 2.4 User Guide
Special commands
73

Advertisement

Table of Contents
loading

Table of Contents