Local At Command Request - 0X08 - Digi XBee S2C 802.15.4 User Manual

Radio frequency module
Table of Contents

Advertisement

Operate in API mode

Local AT Command Request - 0x08

Response
frame: Description
Description
This frame type is used to query or set command parameters on the local device. Any parameter that
is set with this frame type will apply the change immediately. If you wish to queue multiple parameter
changes and apply them later, use the
When querying parameter values, this frame behaves identically to
-
0x09: You can query parameter values by sending this frame with a command but no parameter
value field—the two-byte AT command is immediately followed by the frame checksum. When an AT
command is queried, a Description frame is populated with the parameter value that is currently set
on the device. The Frame ID of the 0x88 response is the same one set by the command in the 0x08
request frame.
Format
The following table provides the contents of the frame. For details on frame structure, see
format.
Offset Size
0
8-bit
1
16-bit
3
8-bit
4
8-bit
5
16-bit
variable Parameter
7-n
EOF
8-bit
Examples
Each example is written without escapes (AP = 1) and all bytes are represented in hex format. For
brevity, the start delimiter, length, and checksum fields have been excluded.
Set the local command parameter
Set the NI string of the radio to "End Device".
The corresponding Description with a matching Frame ID will indicate whether the parameter change
succeeded.
7E 00 0E 08 A1 4E 49 45 6E 64 20 44 65 76 69 63 65 38
XBee/XBee-PRO S2C 802.15.4 RF Module User Guide
Queue Local AT Command Request - 0x09
Frame Field
Description
Start Delimiter
Indicates the start of an API frame.
Length
Number of bytes between the length and checksum.
Frame type
Local AT Command Request - 0x08
Frame ID
Identifies the data frame for the host to correlate with a
subsequent response.
If set to0, the device will not emit a response frame.
AT command
The two ASCII characters that identify the AT Command.
If present, indicates the requested parameter value to set the
value
given register.
(optional)
If no characters are present, it queries the current parameter
value and returns the result in the response.
Checksum
0xFF minus the 8-bit sum of bytes from offset 3 to this byte
(between length and checksum).
Frame descriptions
instead.
Queue Local AT Command Request
API frame
115