AT commands
Special commands
The following commands are special commands.
AC (Apply Changes)
Immediately applies new settings without exiting Command mode.
Parameter range
N/A
Default
N/A
FR (Force Reset)
If you issue FR while the device is in Command Mode, the reset effectively exits Command mode.
Resets the device through the UART. The device responds immediately with an OK and performs a
reset 100 ms later.
Parameter range
N/A
Default
N/A
RE (Restore Defaults)
Restore device parameters to factory defaults.
Parameter range
N/A
Default
N/A
WR (Write)
Writes parameter values to non-volatile memory so that parameter modifications persist through
subsequent resets.
Note
Once you issue a WR command, do not send any additional characters to the device until after
you receive the OK response.
Parameter range
N/A
Default
N/A
XBee®-PRO 900HP/XSC RF Modules
Special commands
76