Digi XBee S2C 802.15.4 User Manual page 121

Radio frequency module
Table of Contents

Advertisement

Operate in API mode
Queue remote command parameter change
Change the PAN ID of a remote device so it can migrate to a new PAN, since this change would cause
network disruption, the change is queued so that it can be made active later with a subsequent AC
command or written to flash with a queued WR command so the change will be active after a power
cycle.
The corresponding
success.
7E 00 11 17 68 00 13 A2 00 12 34 56 78 FF FE 00 49 44 04 51 D8
Frame
type
Frame ID
0x17
0x68
Request
Matches
response
Query remote command parameter
Query the temperature of a remote device—TP command.
The
corresponding Remote AT Command Response-
temperature value.
7E 00 0F 17 FA 00 13 A2 00 12 34 56 78 FF FE 00 54 50 84
Frame
type
Frame ID
0x17
0xFA
Request
Matches
response
XBee/XBee-PRO S2C 802.15.4 RF Module User Guide
Remote AT Command Response-
16-bit
64-bit dest
dest
0x0013A200
0xFFFE
12345678
Unknown Queue Change
16-bit
64-bit dest
dest
0x0013A200
0xFFFE
12345678
Unknown N/A
0x97 with a matching Frame ID will indicate
Command
AT
options
command
0x00
0x4944
"ID"
0x97 with a matching Frame ID will return the
Command
AT
options
command
0x00
0x5450
"TP"
Frame descriptions
Parameter
value
0x0451
Parameter
value
(omitted)
Query the
parameter
121