XBee ZNet 2.5 Command Reference Tables

Special

Table 20: Special commands
AT
Command
Name and Description
WR
Write. Write parameter values to non-volatile memory so that
parameter modifications persist through subsequent resets.
Note
Once WR is issued, no additional characters should be sent
to the module until after the "OK\r" response is received. The WR
command should be used sparingly. The EM250 supports a limited
number of write cycles."
WB
Write Binding Table: Writes the current binding table to non-
volatile memory.
RE
Restore Defaults. Restore module parameters to factory defaults.
RE command does not reset the ID parameter.
FR
Software Reset. Reset module. Responds immediately with an
"OK" then performs a reset ~2 seconds later. Use of the FR
command will cause a network layer restart on the node if SC or ID
were modified since the last reset.
NR
Network Reset. Reset network layer parameters on one or more
modules within a PAN. Responds immediately with an "OK" then
causes a network restart. All network configuration and routing
information is consequently lost.
If NR = 0: Resets network layer parameters on the node issuing the
command.
If NR = 1: Sends broadcast transmission to reset network layer
parameters on all nodes in the PAN.
1. Node types that support the command: C = Coordinator, R = Router, E = End Device.

Addressing

XBee ZNet 2.5 / XBee PRO Znet 2.5 OEM RF Modules Product Manual
Node
Parameter
1
Type
Range
Default
CRE
--
--
CRE
--
--
CRE
--
--
CRE
--
--
CRE
0 - 1
--
Special