AT commands
Special commands
The following commands are special commands.
AC (Apply Changes)
Immediately applies new settings without exiting Command mode.
Parameter range
N/A
Default
N/A
FR (Software Reset)
Resets the device. The device responds immediately with an OK and performs a reset 100 ms later.
If you issue FR while the device is in Command Mode, the reset effectively exits Command mode.
Parameter range
N/A
Default
N/A
RE (Restore Defaults)
Restore device parameters to factory defaults.
In order for the default parameters to persist through subsequent resets, send a separate WR
command after RE.
Parameter range
N/A
Default
N/A
WR (Write)
Writes parameter values to non-volatile memory so that parameter modifications persist through
subsequent resets.
When you issue a WR command add a 100 millisecond delay or wait for an OK response before issuing
any subsequent AT commands.
Note
Once you issue a WR command, do not send any additional characters to the device until after
you receive the OK response.
Parameter range
N/A
XLR PRO Radio Frequency (RF) Module User Guide
Special commands
43