AT commands
Special commands
The following commands are special commands.
WR (Write)
Writes parameter values to non-volatile memory so that parameter modifications persist through
subsequent resets.
If you make changes without writing them to non-volatile memory, the device reverts back to
previously saved parameters the next time the device is powered-on.
Note
Once you issue a WR command, do not send any additional characters to the device until after
you receive the OK response.
Parameter range
N/A
Default
N/A
RE (Restore Defaults)
Restore device parameters to factory defaults.
The RE command does not write restored values to non-volatile (persistent) memory. Issue the WR
(Write) command after issuing the RE command to save restored parameter values to non-volatile
memory.
Parameter range
N/A
Default
N/A
FR (Software Reset)
If you issue FR while the device is in Command Mode, the reset effectively exits Command mode.
Forces a software reset on the device. The reset simulates powering off and then on again the device.
The device responds immediately with an OK and performs a reset 100 ms later.
Parameter range
N/A
Default
N/A
Note
Minimum firmware version required: 1.x80. Firmware versions are numbered in hexadecimal
notation.
XBee/XBee-PRO S1 802.15.4 (Legacy) User Guide
Special commands
47