AT commands

Special commands

The following commands are special commands.

AC (Apply Changes)

Immediately applies new settings without exiting Command mode.
Parameter range
N/A
Default
N/A

FR (Software Reset)

Resets the device. The device responds immediately with an OK and performs a reset 100 ms later.
If you issue FR while the device is in Command Mode, the reset effectively exits Command mode.
Parameter range
N/A
Default
N/A

RE (Restore Defaults)

Restore device parameters to factory defaults.
Parameter range
N/A
Default
N/A

WR (Write)

Writes parameter values to non-volatile memory so that parameter modifications persist through
subsequent resets.
Note
Once you issue a WR command, do not send any additional characters to the device until after
you receive the OK response.
Parameter range
N/A
Default
N/A