Function Description; Overview - Pilz PSENvip R Operating Manual

Safe camera systems
Table of Contents

Advertisement

Function description

4
Function description
4.1

Overview

The detection zone between the transmitter and receiver monitors the immediate danger
zone below the moving upper tool of a press brake. The detection zone moves with the up-
per die, providing mobile safeguarding of the danger zone. The receiver transfers the image
data from the detection zone to the special module PSSu K F FAU. If an object encroaches
into the detection zone, the two outputs on the PSSu K F FAU shut down and the LED on
the receiver goes out. A stop of the press stroke is initiated.
On the productive version, safety functions must be implemented in the PAS4000 user pro-
gram in order to safeguard dynamic muting. Certified Pilz blocks are available for this the
PAS4000 Library.
Incremental encoder
Fig.: Overview of overall system
Operating Manual PSENvip R, PSENvip R LR,PSENvip E
1003449-EN-06
CNC controller
PSSu system with
PSSu K F FAU
Function blocks
(user program)
Safety valve
Prefill valve
PSENvip R/PSENvip R LR
OSSD status
Image fdata
Transmitter PSENvip E
Foot switch
Emergency switching off
E-STOP contactor
Receiver
| 20

Advertisement

Table of Contents
loading

This manual is also suitable for:

Psenvip r lrPsenvip e

Table of Contents