Function description
4.2

Protected field

The protected field consists of several segments. The front and rear segments (viewed
from the operator's side) can be deactivated. This provides flexibility to adapt to the bend-
ing function:
Standard
}
Full protected field: all segments active
Box bending
}
Reduced protected field: front segments deactivated
Bending with back gauge
}
Reduced protected field: rear segments deactivated
Box bending with back gauge
}
Reduced protected field: front and rear segments deactivated
Fig.: Protected field definitions
The height of the protected field depends on the overrun (see
Fig.: Size of the protected field
Operating Manual PSENvip R, PSENvip R LR,PSENvip E
1003449-EN-06
Bending line
Upper tool
Illuminated target area
Rear segments
Workpiece
Lower tool
1 mm
44 mm
Adjustment line
Front segments
Central segments
Overrun [
29])
overrun 2 mm
overrun 14 mm