Function description
Signal/action
Foot switch
Acknowledgement of "re-
duced protected field" pro-
tected field mode
System-Init
OSSD
Mute
Muting OSSD
Monitoring of braking ramp
Monitoring of pinch point
Downward movement, advance measuring field touches workpiece at the pinch
}
point (KP)
Protected field: Free
Dynamic muting: Start
Position = Protected field height (including reserve + advance measuring field)
Position = <Configured overrun> + 6 mm + 2 mm – (2 mm from first muting stage)
Position = <Configured overrun> + 6 mm
Signal/action
Foot switch
Acknowledgement of "re-
duced protected field" pro-
tected field mode
System-Init
OSSD
Mute
Muting OSSD
Monitoring of braking ramp
Monitoring of pinch point
Downward movement, gradual reduction of protected field
}
Protected field: Free
Dynamic muting: Active
Position = Protected field height (including reserve + advance measuring field)
Position = <Configured overrun> + (6 mm + 2 mm) – (2 mm x number of muting stages)
Example for 2nd muting stage: Position = <Configured overrun> + 4 mm
Operating Manual PSENvip R, PSENvip R LR,PSENvip E
1003449-EN-06
Status
Press
1
0 -> 1
0
1
1
Inactive
Inactive
Inactive
Status
Press
1
1 or 0
0
1
1 -> 0
Inactive
Start
Active
KP
| 58