Function description
4.2.1.4

Box bending with back gauge protected field mode

With box bending with back gauge protected field mode, both the rear and front segments
of the protected fields are blanked. This protected field mode is applied for workpieces that
need to be bent several times, e.g. boxes, and when the rear back gauge extends into the
vicinity of the bending line. Interruption of the front and rear segments is to be expected and
does not cause the press stroke to stop.
The central segments of the protected field are behind the bending line. The box's side
panels must not encroach into the central segments.
If the middle segments of the protected field are interrupted, the outputs of the special mod-
ule PSSu K F FAU shut down.
Fig.: Box bending with back gauge protected field mode
Legend
1: Rear segments of protected field are blanked
}
2: Front segments of protected field are blanked
}
The box bending with back gauge protected field mode is only active for one press stroke
and must be acknowledged by the operator before or during the press stroke.
Operating Manual PSENvip R, PSENvip R LR,PSENvip E
1003449-EN-06
1
WARNING!
Risk of injury due to reduced protected field!
Around the bending line there is an increased risk of crushing and trapping
of fingers or hands because the front and rear segments of the protected
field are blanked.
Make sure that the workpiece is handled correctly.