Commissioning
7.2.2.2

Adjustment in the web interface

Open the Tool change page in the web interface. You will see the tool centre point with
guides.
Example of the representation:
1: Tool centre point
}
2: Range bar
}
3: Adjustment line
}
4: Central and rear bending line
}
The vertical position of the tool centre point must be within the range bar. If the adjustment
line is at the upper or lower end of the range bar, the
of range" message will be displayed.
If the
by the transmitter:
Check that the transmitter and receiver are aligned correctly. The illuminated target area
}
must completely envelop the receiver. If necessary, realign the transmitter (see
transmitter [
Remove any potential contamination on the lens of the transmitter or receiver.
}
The adjustment has been carried out correctly when none of the symbols appear:
Accept the adjustment by pressing Accept. The button switches to the function Confirm.
}
Confirm the adjustment within 3 seconds by pressing Confirm.
You can exit the menu at any time without confirming by Cancel or select another option. In
this case, the previous tool data will be retained.
Operating Manual PSENvip R, PSENvip R LR,PSENvip E
1003449-EN-06
symbol appears on the display, there is a problem with the lighting of the receiver