System Cycle For Standard Press Stroke - Pilz PSENvip R Operating Manual

Safe camera systems
Table of Contents

Advertisement

Function description
4.9.1

System cycle for standard press stroke

PSENvip transfers position values to the special module PSSu K F FAU P (see I/O data
type PROTECTION_FIELD_SIZE), which can be used in the user program for feasibility
testing.
A press stroke with full protected field has the following states:
Press is at top dead centre
}
Protected field: Free
Dynamic muting: Inactive
Position = Protected field height (including reserve + advance measuring field)
Position = <Configured overrun> + 6 mm + 2 mm
Signal/action
Foot switch
System-Init
OSSD
Mute
Muting OSSD
Monitoring of braking ramp
Monitoring of pinch point
Downward movement (rapid traverse)
}
Protected field: Free
Dynamic muting: Inactive
Position = Protected field height (including reserve + advance measuring field)
Position = <Configured overrun> + 6 mm + 2 mm
Signal/action
Foot switch
System-Init
OSSD
Mute
Muting OSSD
Monitoring of braking ramp
Monitoring of pinch point
Downward movement, advance measuring field touches workpiece at the pinch
}
point (KP)
Operating Manual PSENvip R, PSENvip R LR,PSENvip E
1003449-EN-06
Status
Press
0
1
1
1
Inactive
Inactive
Inactive
Status
Press
1
0
1
1
Inactive
Inactive
Inactive
v = 0
v > 0
TDC
| 53