Check After Modification - Pilz PSENvip R Operating Manual

Safe camera systems
Table of Contents

Advertisement

Change, maintenance
10.2

Check after modification

After each modification, the safeguards and protection measures on the press brake
must be checked. For example, modifications may be: Tool change, adjustment of over-
run, change of user program, Firmware update or exchange of PSENvip and/or compon-
ents on the PSENvip.
Operating Manual PSENvip R, PSENvip R LR,PSENvip E
1003449-EN-06
INFORMATION
Before modifying a safe process/a safe machine, the impact of the modifica-
tion on the safety of the process/machine must be analysed.
– If the analysis has shown that safety functions need to be validated
and tested after the modification, then both the modification itself and
the course of the entire process must be inspected.
– Modifications should only be carried out by persons with the neces-
sary knowledge and experience (competent persons).