Commissioning
Tool class 2
The contour of these tools is fully detected by the PSENvip.
}
The front (V2) and rear (H2) bending lines are within the protected field.
}
The front segments of the protected field are less than 15 mm away from the front bend-
}
ing line.
These tools are not safeguarded in compliance with the standards.
}
Example:
}
Fig.: Example for tool class 2
Operating Manual PSENvip R, PSENvip R LR,PSENvip E
1003449-EN-06
<15 mm
H
V