Pilz PSENvip R Operating Manual page 63

Safe camera systems
Table of Contents

Advertisement

Function description
Downward movement is stopped, full protected field meets workpiece
}
Protected field: Interrupted
Dynamic muting: Inactive
Position = Protected field height (including reserve + advance measuring field)
Position = <Configured overrun> + 6 mm + 2 mm
Signal/action
Foot switch
Acknowledgement of "re-
duced protected field" pro-
tected field mode
System-Init
OSSD
Mute
Muting OSSD
Monitoring of braking ramp
Monitoring of pinch point
Downward movement is continued with reduced protected field, start via acknow-
}
ledgement
Protected field: Free
Dynamic muting: Inactive
Position = Protected field height (including reserve + advance measuring field)
Position = <Configured overrun> + 6 mm + 2 mm
Signal/action
Foot switch
Acknowledgement of "re-
duced protected field" pro-
tected field mode
System-Init
OSSD
Mute
Muting OSSD
Monitoring of braking ramp
Monitoring of pinch point
Downward movement, advance measuring field touches workpiece at the pinch
}
point (KP)
Protected field: Free
Dynamic muting: Start
Operating Manual PSENvip R, PSENvip R LR,PSENvip E
1003449-EN-06
Status
Press
1
0
0
1 -> 0
1
Inactive
Inactive
Inactive
Status
Press
1
0 -> 1
0
1
1
Inactive
Inactive
Inactive
v = 0